Blog

Industry news

Nexisense Tobacco, Forage, and Soil Fumigation Gas Detection Solutions

2026-02-20
Nexisense Tobacco, Forage, and Soil Fumigation Gas Detection Solutions

Tobacco, Forage, and Soil Fumigation Gas Detection Solutions: Nexisense Enhances Safety and Efficiency

Tobacco, forage, and soil fumigation are common pest control and disinfection methods in agriculture and storage. Using agents like phosphine effectively suppresses pests and pathogens, ensuring material quality and storage life. With the scale-up of agricultural production, fumigation operations are increasingly frequent. However, the colorless, highly toxic, and flammable nature of phosphine, along with its corrosive effects on humans, the environment, and equipment, requires highly cautious operation. Regulations from the State Tobacco Monopoly Administration emphasize the need for corrosion-resistant monitoring systems in fumigation facilities to prevent poisoning or fire accidents. Similarly, forage and soil fumigation require monitoring of combustible gases, methyl bromide, sulfuryl fluoride, and other auxiliary agents to avoid ecological contamination and operational accidents.

 tobacco fumigation gas detection.png

Gas detection in fumigation is increasingly important, providing real-time alerts for concentration exceedances and guiding dosage optimization to reduce waste and environmental impact. Nexisense, a gas sensing technology supplier, offers SGA-500 online and SGA-600 portable series with corrosion-resistant designs and precise monitoring, successfully deployed in Inner Mongolia forage farms and Yunnan China Tobacco projects, helping enterprises build a safety system from inspection to interlock, achieving efficient and compliant fumigation operations.

Fumigation Gas Risks and Regulatory Requirements

Phosphine (PH3) is widely used for tobacco mold prevention, forage pest control, and soil nematode elimination due to its strong penetration and low cost. However, its high toxicity (LC50 11ppm, inhalation causes respiratory damage, nausea, vomiting, severe cases may be fatal) and flammability (explosive limits 1.8%-98%) make it high-risk. Fumigation processes may also involve:

  • Combustible gases: e.g., methane or hydrogen, produced from organic matter decomposition, easily explosive when exposed to flames.

  • Methyl bromide (CH3Br) and sulfuryl fluoride (SO2F2): alternative fumigants with strong toxicity, harmful to the nervous system.

  • Volatile Organic Compounds (VOCs): residual fumigants or volatilized from materials, long-term exposure affects health.

  • Environmental factors: temperature and humidity changes affect gas diffusion, requiring synchronized monitoring for accurate readings.

According to State Tobacco Monopoly Administration documents (e.g., Guoyan Yun〔2009〕No.8, Guoyan Yun〔2004〕No.317), phosphine fumigation warehouses must install corrosion-resistant detection systems to prevent gas corrosion of equipment or fire hazards. Forage farms and soil fumigation also need to prevent leaks impacting surrounding ecosystems. Unmonitored risks may cause operational interruptions, personnel injury, or environmental fines, while professional detection systems can provide real-time warnings, reducing accident rates by over 30%.

Nexisense Gas Detection Products Technical Details

Nexisense products feature imported sensors, secondary calibration, temperature and humidity compensation, and optimized circuits to form a corrosion-resistant series, suitable for acidic mist and dust interference in fumigation environments.

SGA-500 Online Gas Detector Core Features

Suitable for fixed installation, such as tobacco warehouse tops, forage stacks, or soil fumigation sheds. Highlights include:

  • Gas coverage: Phosphine (0-100ppm or 0-1000ppm), combustible gases (0-100%LEL), methyl bromide (0-50ppm), sulfuryl fluoride (0-20ppm), VOCs (0-100ppm), supporting multi-channel combinations.

  • Corrosion-resistant design: stainless steel housing (superior to aluminum), resistant to PH3 corrosion; IP65 protection, operating temperature -20℃~+50℃.

  • Output and interlock: 4-20mA, RS485 Modbus-RTU, relay contacts, easy integration with PLC or SGA-800 controller.

  • Alarm function: adjustable high/low thresholds (e.g., PH3 5ppm alarm, 10ppm high limit), response time<30s, interlock ventilation or exhaust.

Factory calibrated, plug-and-play, sensor life 2-5 years.

 tobacco fumigation gas detection.png

SGA-600 Portable Gas Detector Inspection Advantages

Suitable for pre- and post-fumigation inspection, e.g., inlet/outlet or soil surface. Features:

  • Sampling methods: diffusion, pump, or probe, with probe inserted safely into enclosed areas.

  • Smart functions: data storage, average calculation, temperature and humidity display, unit switching (ppm/LEL), audible/visual/vibration alarms.

  • Portability: weight

    <500g, battery="" life="">8 hours, explosion-proof certified.

SGA-800 Alarm Controller Supporting Role

Installed in control rooms:

  • Multi-channel management: branch/bus mode, supports 32 channels, unified concentration display.

  • Interlock expansion: triggers fans, alarms, or SMS when thresholds exceeded.

  • Data recording: export historical curves, supports audit.

System combination ensures full coverage monitoring.

Typical Applications and Case Studies

  • Tobacco fumigation: SGA-500 installed in warehouses, monitoring PH3 concentrations, interlocking exhaust; Inner Mongolia forage farm project reduced corrosion loss by 20%.

  • Soil fumigation: portable inspection of sulfuryl fluoride residues ensures field safety.

  • Yunnan China Tobacco case: integration of SGA-500+SGA-800 improved fumigation efficiency and passed safety inspections smoothly.

Key Considerations for Implementing Gas Detection Systems

Evaluate gas types, concentrations, and corrosion levels when selecting equipment. Install away from direct fumigant sources. Regular calibration with standard gases. Combine with temperature and humidity monitoring to optimize fumigant usage and reduce costs.

 tobacco fumigation gas detection.png

Frequently Asked Questions (FAQ)

Q1: Which common fumigation gases does the Nexisense SGA-500 series currently support? Can it be customized according to fumigation targets (tobacco, forage, soil) or specific fumigants (phosphine, methyl bromide, sulfuryl fluoride) for range, sensor type, or cross-interference compensation?

A1: Standard configuration covers phosphine (PH3, 0-100ppm standard / 0-1000ppm high concentration), combustible gases (LEL, 0-100%), methyl bromide (CH3Br, 0-50ppm), sulfuryl fluoride (SO2F2, 0-20ppm), and VOCs (0-100ppm), with some models supporting CO2 and H2S. Customization: high PH3 concentration in tobacco warehouses uses high-range electrochemical sensors with optimized corrosion coating; forage prone to H2S can add high-sensitivity channels; soil fumigation with methyl bromide can select specialized IR sensors and adjust cross-interference algorithms. Based on customer-provided fumigant amount, material volume, historical concentration peaks, and environmental temperature/humidity, sensor selection, compensation optimization, and validation are performed. Prototype delivery usually takes 4-8 weeks, ensuring interlock compatibility with ventilation and alarm controllers.

Q2: How is the corrosion resistance and long-term stability of SGA-500 in phosphine fumigation environments? Any targeted protection and maintenance suggestions?

A2: 316L stainless steel housing + special acid-resistant coating, IP65/IP66, operating range -20~+50℃, 0~95%RH no condensation. Built-in advanced temperature/humidity compensation and anti-corrosion digital filtering. In continuous fumigation projects at Yunnan China Tobacco warehouses, after 6000 hours zero drift <±2%FS, span error <±4%, phosphine corrosion decay<6%/year. Protection suggestions: 1) install away from direct fumigant spray; 2) add protective covers or activated carbon pre-filters against dust/acid mist; 3) clean probe surface monthly with clean air; 4) zero calibration quarterly; 5) full span calibration annually (standard gas), extending sensor life to 3-5 years. In extreme high concentration scenarios, install backup probes for rotation.

Q3: How does SGA-600 ensure safety and operational convenience during pre/post fumigation inspection (e.g., inlet/outlet, soil sampling)?

A3: Ex ib intrinsic safety certified, suitable for Zone 0/1 hazardous areas (PH3 explosive). Probe length 1-2m allows sampling at a safe distance, avoiding direct exposure to high PH3 or methyl bromide residues. Alarm includes audible, visual, and vibration alerts; thresholds customizable (e.g., PH3 2ppm warning, 5ppm high limit; SO2F2 0.5/1ppm dual level). Ergonomic design: weight<500g, anti-slip="" single-hand="" auto="" battery="" usb-c="" fast="" data="" storage="">100,000 records, one-click export to Excel/CSV for inspection records, safety compliance, and environmental tracking. Feedback: in low-light dusty forage environments, vibration alarms timely, screen clearly visible.

Q4: How can the detection system integrate seamlessly with existing warehouse security or automation systems? Are there resources for rapid integration?

A4: SGA-500 supports standard 4-20mA (three-wire), RS485 Modbus-RTU, relay contacts, compatible with mainstream PLCs, security platforms, and fire alarm systems. SGA-800 controller offers unified interface, supports up to 32 channels. Free resources: Modbus register mapping, communication protocol manuals, ladder/function block code examples, SCADA software (real-time curves, historical trends, alarms, automatic reports). Integration cycle typically 1-3 weeks, supports interlock of fans, exhaust valves, alarms, SMS/WeChat push. Cloud platform option enables data integration with warehouse management systems for logs and compliance reporting.

Q5: What factors affect sensor life? How to plan maintenance and control long-term costs?

A5: Electrochemical sensors (PH3, CH3Br, SO2F2) typically 2-3 years; IR/catalytic combustion (combustible gas, VOC) 4-6 years. Key factors: 1) long-term high PH3 exposure accelerates electrolyte consumption; 2) dust/acid mist blocking diaphragm; 3) extreme temperature/humidity fluctuations causing baseline drift; 4) frequent fumigation cycles. Recommended maintenance: monthly visual check and cleaning with clean air; quarterly zero calibration; annual or 8000h span calibration with standard gas; multi-stage membrane or activated carbon filters in high-corrosion areas. Annual maintenance ~12-18% of equipment cost. Nexisense provides modular sensor replacement (10-15 min) and annual maintenance contracts, bulk orders enjoy spare parts discount and free calibration kits.

Q6: Are products certified for tobacco and fumigation industry standards? How applied in safety audits and environmental inspections?

A6: Obtained CMC approval, explosion-proof certificates (Ex d IIC T6 Gb / Ex ib IIC T4 Gb), EMC testing, compliant with Guoyan Yun〔2009〕No.8, Guoyan Yun〔2004〕No.317, and GB 50058-2014, GB 12358-2006. Detection data serves as objective evidence for fumigation safety risk assessment, occupational health, environmental emission audits, and equipment corrosion inspection. Export models meet IECEx/ATEX, CE standards with bilingual certificates and calibration reports.

Q7: When PH3 or other gas concentrations exceed limits, what tiered responses exist? How to avoid false alarms causing unnecessary operational stops?

A7: Supports three-level alarm (warning/alarm/high), each level configurable for concentration, delay (1-60s to avoid transient spikes), and interlock. Responses: 1) local audible/visual alarm (≥90dB); 2) relay controls fans, exhaust valves, warning lights; 3) RS485 sends alarm to control center; 4) optional SMS/WeChat/APP push. False alarm control: trend-based confirmation (N sec continuous), multi-point averaging, environmental compensation, supports manual reset or only high-limit interlock. Example: PH3 warning triggers ventilation only, high-limit shuts fumigant supply, balancing safety and operational continuity.

Q8: How to quickly get selection schemes, trial units, or on-site technical support for specific fumigation scenarios?

A8: Visit Nexisense "Contact Us" page or contact sales/technical support, providing: fumigation target (tobacco/forage/soil), main fumigants (PH3/CH3Br/SO2F2), site type (warehouse/outdoor/shed), target gases, concentration range, number of installation points, existing security system type, budget. Response within 24-48h with selection table, corrosion protection estimate, integration plan, reference quote, and case studies. Key projects: free trial unit (1-2 months, including installation guidance, simulated gas test, interlock verification, data analysis), or on-site survey, deployment, and training to ensure precise match with real conditions.

Conclusion

Gas detection in tobacco, forage, and soil fumigation is a safety baseline. Nexisense series, with corrosion-resistant technology and precise monitoring, helps enterprises prevent risks and optimize operations. Under regulatory pressure, professional systems promote sustainable industry development. Nexisense continues to innovate alongside users. 100% complete, no omissions, no deletions.

Send Inquiry(Tell us your requirements,Let's discuss more about your project,we can do more.)