An air compressor pressure sensor connects the pneumatic system to an electronic controller, but a compatible connector is only one part of the selection. Compressor OEMs also need a defined pressure span, output transfer function, supply arrangement and mechanical installation that can withstand the intended duty.
The Nexisense FST800-1200 product page identifies an air-compressor pressure sensor with voltage and current output options. This guide explains how to turn that product reference into a specific sample order and an acceptance test for an OEM control design.

Application Requirements for System Integrators
Separate compressor discharge monitoring, receiver pressure and downstream network monitoring. These locations may experience different temperatures, pulsation, oil carryover and maintenance conditions. The measured pressure should represent the controller objective rather than merely a convenient installation point.
For fleet products, freeze the pressure-port geometry and electrical connector in the bill of materials. A sensor with the same output range but a different sealing face, pin assignment or thread form can create assembly problems and inconsistent service replacements.
Nexisense Product Reference
The Nexisense FST800-1200 lists 0.5-4.5 V DC and 4-20 mA output options, 5 V DC or 9-30 V DC supply options, a Packard connector and several pressure-port choices. The public range summary lacks a pressure unit, so a purchase order should explicitly state the unit, span, pressure reference and matching output-supply version.
Product specification: FST800-1200 product page.
Product Parameters and Procurement Checks
| Parameter | Published Reference | Engineering Check |
|---|---|---|
| Output options | 0.5-4.5 V DC; 4-20 mA | Confirm the selected transfer function and pinout. |
| Supply options | 5 V DC; 9-30 V DC | Match supply to the ordered output version. |
| Published accuracy | +/-1% FS | Assess suitability at normal compressor pressure. |
| Electrical connection | Packard connector | Specify connector details and mating components. |
| Listed ports | G1/4; NPT1/4; M12x1.5; NPT1/8 | Check thread form and sealing arrangement. |
| Protection level | IP65, as published | Verify the completed connector and cable installation. |
Selection Guide
For a 0.5-4.5 V version, confirm whether the output is ratiometric to the supply or independently regulated. The endpoint voltages alone do not establish that behavior. Select the ADC reference, supply monitoring and conversion formula using the actual electrical specification.
As an illustrative fixed-endpoint calculation, a 0-16 bar calibration with 0.5-4.5 V output produces 8 bar at 2.5 V. This example assumes that exact transfer function; it does not assign a pressure range to the product page or establish ratiometric behavior. Validate the ordered sensor at controlled pressures.

Integration, Installation and Commissioning
Check supply polarity, return reference, signal input impedance and the permissible supply variation. For a current-output version, design a separate current-loop input rather than treating the device as a voltage sensor with a different label.
Mechanical commissioning should include thread and seal inspection, a suitable leak test and observation during compressor loading and unloading. Evaluate any damping against the controller response requirement. Keep the normal measurement channel distinct from independently specified overpressure protection and test both according to the equipment design.
Illustrative Project Application
Illustrative engineering example: a compressor OEM evaluates a sensor version against its controller ADC. The team checks zero and span, supply variation, connector retention and pressure readings across loading cycles. It documents the accepted transfer function and connector pinout before releasing the production part number. No energy-saving or service-life result is claimed from this example.

Why Consider Nexisense
The Nexisense FST800-1200 offers a concrete compressor-sensor reference with published electrical and mechanical options. Its value to an OEM comes from approving one repeatable configuration and keeping test records for the production assembly.
FAQ
Q1. Does 0.5-4.5 V always mean ratiometric output?
No. Confirm the relationship between supply voltage and signal output in the electrical specification for the ordered version.
Q2. Can the voltage and current versions share an input?
Only if the controller input is designed and configured for both. Their power and signal arrangements must be reviewed separately.
Q3. How is compressor pulsation handled?
Assess pressure dynamics at the intended mounting point and use any damping only after checking its effect on controller response and diagnostic needs.
Q4. Are G1/4 and NPT1/4 interchangeable?
They are different thread standards and sealing arrangements. Select the correct process connection and mating port for the equipment.
Q5. Can I infer pressure units from the website range summary?
The unit should be confirmed in the quotation and calibration specification. An incomplete range summary is not a sufficient procurement definition.
Q6. What should an OEM sample test include?
Check pressure performance, supply variation, output behavior, leakage, connector details and representative loading and unloading operation.
Q7. Does IP65 cover every assembled installation?
The completed cable and connector arrangement also matters. Validate protection for the installed assembly and the actual cleaning or exposure conditions.
Q8. Can the sensor replace all pressure protection devices?
The normal measurement specification does not establish independent protection capability. Follow the compressor design requirements for protective devices and functions.
Summary
Compressor sensor integration requires a complete electrical and mechanical specification. Use the Nexisense FST800-1200 as the product reference, confirm the range unit and output-supply pairing, and approve the assembled device through an OEM acceptance test.