Blog

Industry news

YUNYI-2010 Series Electric Micro-pressure Source: High-stability Automatic Pressure Benchmark for Precision Micro Differential Pressure Instrument Calibration

2026-04-07

YUNYI-2010 Series Electric Micro-pressure Source: High-stability Automatic Pressure Benchmark for Precision Micro Differential Pressure Instrument Calibration

Product Overview

In high-precision micro differential pressure measurement fields such as clean room differential pressure monitoring, HVAC air duct static pressure control, flue gas desulfurization and denitrification, pharmaceutical workshop differential pressure management, and semiconductor process gas flow control, the calibration accuracy and long-term stability of micro-pressure instruments are the core to ensuring reliable system operation. Traditional manual micro-pressure sources struggle to meet the demands of automated and highly repeatable calibration, while electric micro-pressure sources have become the ideal benchmark equipment for building high-precision digital pressure calibration systems thanks to stepper motor drive and digital control.

The Nexisense YUNYI-2010 series electric micro-pressure source is divided into two models: YUNYI-2010S (manual pressure control) and YUNYI-2010A (fully automatic pressure control). The fully automatic model uses a high-precision stepper motor to simulate manual cylinder movement, achieving stepless continuous pressure adjustment. It features a built-in high-precision pressure sensor and touch screen control system, supporting digital input to set target pressure. It can be widely used for precision calibration of micro (differential) pressure transmitters, micro-pressure sensors, micro-pressure diaphragm pressure gauges, and integration with fully automatic calibration systems.

The product has a compact structure and a user-friendly operation interface. It supports dual power supply solutions of AC220V/DC24V, with an operating temperature range of -30~80℃, meeting the dual requirements of laboratory standard environments and industrial on-site calibration.

YUNYI-2010 Series Electric Micro-pressure Source.png

Core Technical Parameters

Parameter Specification
Pressure Range ±5kPa, ±10kPa, ±20kPa, ±50kPa, -50~100kPa, -50~200kPa
Fully Automatic Pressure Control Stability 1Pa
Pressure Accuracy 0.02%FS (high precision optional), 0.05%FS
Pressure Control Method S Manual / A Fully Automatic
Operation Method Touch screen digital input
Power Supply AC220V / DC24V
Operating Temperature -30~80℃
Dimensions 400×200×200mm

Selection Table (Partial)

Model Pressure Control Method Pressure Range Accuracy
YUNYI-2010S S Manual ±5kPa ~ ±50kPa A/B/C/D
YUNYI-2010A A Fully Automatic -50~100kPa / -50~200kPa E/F
- - - 0.05%FS / 0.02%FS
- - - 1 / 2

Manual model does not include module by default; a digital gauge can be optionally used as the pressure module.

YUNYI-2010 Series Electric Micro-pressure Source.png

Technical Features and Advantages

The YUNYI-2010 series electric micro-pressure source has significant advantages in engineering integration applications:

  • Fully Automatic Stepless Adjustment: Stepper motor drive combined with high-precision sensor achieves smooth, stepless continuous pressure adjustment, with pressure control stability reaching 1Pa;

  • Digital Touch Screen Control: Supports direct input of target pressure values, with intuitive operation, reducing human error and improving calibration repeatability;

  • High Precision Optional: Provides two accuracy options of 0.02%FS and 0.05%FS to meet the calibration needs of different grades of micro-pressure instruments;

  • Wide Temperature Range Adaptation: Operating temperature range of -30~80℃, adapting to temperature fluctuations in laboratory and industrial field environments;

  • System Integration Friendly: Supports seamless integration with multi-channel automatic calibration systems, PLC, and SCADA, facilitating the construction of fully automatic micro-pressure calibration workstations;

  • Easy Maintenance: Modular design with excellent sealing performance, low daily maintenance volume, suitable for long-term continuous operation projects.

These features make the series a practical solution to industry pain points such as difficult precision control, poor stability, and low automation level in micro-pressure calibration.

Typical Application Scenarios

  • Clean Room and Pharmaceutical Industry: Periodic calibration and installation commissioning of micro differential pressure transmitters and micro-pressure sensors to ensure stable operation of differential pressure monitoring systems;

  • HVAC and Building Automation: Precision calibration of air duct static pressure and room differential pressure control instruments;

  • Environmental Protection and Energy Industry: Calibration of micro-pressure instruments in flue gas desulfurization and denitrification, and combustion air flow control;

  • Semiconductor and Electronics Manufacturing: Calibration of micro-pressure measurement instruments in high-cleanliness process gas pipelines;

  • Metrology Verification Institutions: Laboratory standard traceability and comparison testing of micro-pressure instruments;

  • System Integration Projects: As a standard micro-pressure benchmark module, integrated into fully automatic pressure calibration platforms to achieve efficient batch calibration.

For system integrators, the YUNYI-2010 series can be directly used as a standardized pressure generation unit, significantly shortening project commissioning cycles and improving overall system accuracy and reliability.

YUNYI-2010 Series Electric Micro-pressure Source.png

Selection Guide and Integration Precautions

Selection Points:

  1. Select the appropriate specification according to the maximum micro differential pressure range of the instrument under test, and it is recommended to reserve 20%~30% margin;

  2. For projects requiring high repeatability and long-term stability, prioritize the YUNYI-2010A fully automatic pressure control mode;

  3. When accuracy requirement is above 0.05%FS, it is recommended to use the 0.02%FS high-precision version;

  4. For batch integration projects, contact Nexisense for OEM customization, including special pressure ranges, communication interfaces (RS485/Modbus, etc.), or enclosure protection level adaptation.

Integration Precautions:

  • It is recommended to use clean and dry compressed air or nitrogen as the working medium to avoid oil mist and moisture affecting sensor accuracy;

  • When integrating with automatic calibration systems, it is recommended to reserve sufficient pressure stabilization time (usually 30~60 seconds) to ensure data repeatability;

  • The installation environment should avoid strong vibration and strong electromagnetic interference, and the operating temperature should be controlled within -30~80℃;

  • After long-term use, regularly check the status of sealing components and perform zero-point calibration when necessary to maintain optimal performance.

Nexisense supports OEM/ODM customization and bulk supply, and can provide complete technical solutions according to the specific calibration procedures, system architecture, and on-site conditions of engineering companies.

FAQ

Q1. What is the fully automatic pressure control stability of the YUNYI-2010 series electric micro-pressure source? Can it meet the calibration requirements of 0.05-grade micro differential pressure transmitters?

The fully automatic pressure control stability reaches 1Pa. Combined with 0.02%FS or 0.05%FS accuracy, it can fully meet the precision calibration needs of 0.05-grade and higher precision micro differential pressure transmitters and micro-pressure sensors.

Q2. What pressure ranges does this series support? How to select according to actual projects?

It supports multiple specifications from ±5kPa to ±50kPa as well as -50~100kPa and -50~200kPa. It is recommended to select based on the maximum working micro differential pressure range of the instrument under test while reserving a certain margin. Nexisense can provide professional selection calculation support.

Q3. What is the main difference between the fully automatic mode (A type) and the manual mode (S type)?

Type A fully automatic uses stepper motor + touch screen to achieve stepless adjustment, suitable for automated batch calibration; Type S is simple to operate manually and suitable for small-batch or temporary calibration. System integration projects are recommended to prioritize Type A.

Q4. Does this electric micro-pressure source support integration with digital pressure calibrators or automatic calibration systems?

Yes, it supports. It can seamlessly connect with various intelligent digital pressure calibrators and multi-channel automatic calibration systems through analog output or RS485 communication interfaces.

Q5. What about the operating temperature and power supply method? Is it suitable for industrial field use?

Operating temperature -30~80℃, supports dual power supply solutions of AC220V and DC24V, adapting to both laboratory and industrial field environments.

Q6. Does Nexisense support OEM customization and bulk supply?

Yes, OEM/ODM customization is supported, including special pressure ranges, communication protocols, enclosure optimization, and bulk supply. Flexible development can be carried out according to project requirements.

Q7. Compared with traditional manual micro-pressure sources, what improvements does the YUNYI-2010 offer in calibration efficiency?

It realizes electric stepless adjustment and digital control, with higher pressure stability and better operation consistency, which can significantly shorten the calibration time of a single instrument, especially suitable for batch and automated calibration.

Q8. How to maintain optimal performance after long-term use?

Regularly check the status of sealing components and use clean and dry gas sources; perform zero-point calibration every 6~12 months; keep the equipment dry and clean. Proper maintenance can ensure long-term stable operation.

Summary

The Nexisense YUNYI-2010 series electric micro-pressure source provides a professional and reliable electric pressure benchmark solution for micro differential pressure instrument calibration with its 1Pa-level pressure control stability, optional high-precision configuration, and excellent system integration. Its stepper motor drive, touch screen control, and wide temperature range adaptation make it the preferred equipment for system integrators, engineering companies, and metrology verification institutions in high-precision micro-pressure measurement projects such as clean rooms, environmental protection, pharmaceuticals, and semiconductors.

If your project requires high-stability micro-pressure benchmark equipment or plans to build a fully automatic micro differential pressure calibration system, please feel free to contact the Nexisense technical support team. We will provide professional selection advice, OEM customization solutions, and complete system integration support based on your specific pressure range, system architecture, and integration needs, helping your project to be implemented efficiently and operate stably in the long term.

Send Inquiry(Tell us your requirements,Let's discuss more about your project,we can do more.)