XY-1 Pressure Gauge Adapter Kit (38-Piece Set): Multi-Specification Instrument Calibration Quick Adapter Solution
Nexisense XY-1 Pressure Gauge Adapter Kit (38-Piece Set) is a professional adapter toolbox specially designed for metering verification institutions, instrument and meter manufacturing enterprises, and engineering field calibration teams. The kit uses M20×1.5 as the benchmark interface and systematically includes the most commonly used thread specifications for domestic and international pressure gauges and pressure transmitters. It enables quick conversion between different interfaces, completely solving the problem of low efficiency caused by interface mismatch during the calibration process.
Product Overview
The XY-1 adapter kit is precision-machined from high-quality stainless steel material, featuring high thread accuracy, excellent sealing performance, and strong pressure resistance. It can be used repeatedly. The entire set includes 38 common adapter pieces and 70 matching sealing elements, covering various combinations of internal and external threads. It is suitable for the calibration and testing of pressure gauges, precision pressure gauges, digital pressure gauges, pressure transmitters, pressure sensors, and other instruments.
The product design fully considers actual calibration scenario requirements. It includes dedicated transition adapters for axial gauges and oxygen pressure gauges, as well as φ6, φ8, and φ10 barb adapters. It meets the dual needs of laboratory standard verification and rapid field calibration, making it an essential tool for pressure metering laboratories and instrument maintenance departments.
Specific Specification List
| Specification | Internal Thread | External Thread |
|---|---|---|
| M20×1.5 | 1 pc | 1 pc |
| G1/2 | 1 pc | 1 pc |
| NPT1/2 | 1 pc | 1 pc |
| M16×1.5 | 1 pc | 1 pc |
| G3/8 | 1 pc | 1 pc |
| NPT3/8 | 1 pc | 1 pc |
| M14×1.5 | 1 pc | 1 pc |
| G1/4 | 1 pc | 1 pc |
| NPT1/4 | 1 pc | 1 pc |
| M12×1.25 | 1 pc | 1 pc |
| G1/8 | 1 pc | 1 pc |
| NPT1/8 | 1 pc | 1 pc |
| M10×1.0 | 1 pc | 1 pc |
| ZG1/2 | 1 pc | 1 pc |
| ZG3/8 | 1 pc | 1 pc |
| ZG1/4 | 1 pc | 1 pc |
| ZG1/8 | 1 pc | 1 pc |
Additional Items:
• φ6, φ8, φ10 barb adapters: 1 pc each
• Dedicated transition adapters for axial gauges and oxygen pressure gauge verification: 1 set
Included Accessories: 70 sealing elements of various specifications (including O-rings, gaskets, etc.)
Product Features
-
Full set made of high-quality stainless steel: high strength, corrosion resistance, oxidation resistance, and long service life
-
Complete thread specifications: one set solves interface conversion difficulties for various domestic and international pressure instruments
-
Excellent sealing performance: paired with 70 sealing elements to ensure no leakage during calibration
-
Compact structure: easy to carry and quick to replace on site
-
Includes dedicated transition adapters: compatible with axial pressure gauges and oxygen pressure gauge calibration
-
Standardized design: strong interchangeability, convenient for daily maintenance and spare parts management
Typical Application Scenarios
-
Metering verification institutions: periodic verification and comparison testing of pressure gauges and precision pressure gauges
-
Instrument and meter manufacturing enterprises: factory calibration and quality control
-
Petroleum, chemical, power, and metallurgical industries: rapid on-site calibration of pressure transmitters and pressure sensors
-
Laboratories and calibration centers: multi-specification instrument interface conversion and standard traceability
-
Engineering companies: interface adaptation during pressure instrument installation, commissioning, and maintenance
This adapter kit is particularly suitable for occasions requiring frequent calibration of instruments with different interfaces. It can significantly shorten calibration preparation time and improve work efficiency.
Selection and Usage Guide
Selection Recommendations
-
Standard metering laboratories are recommended to choose the full XY-1 38-piece set for the most comprehensive coverage.
-
Field maintenance teams can select sub-kits based on commonly used specifications.
-
For oxygen medium applications, please use the dedicated oil-free processed transition adapters.
Usage Precautions
-
When installing, select the corresponding adapter according to the instrument interface and pay attention to internal/external thread matching.
-
Check the integrity of sealing elements before each use and replace them promptly if necessary.
-
Use moderate tightening torque to avoid over-tightening and damaging threads.
-
Clean the adapter surface promptly after use and store it properly to extend service life.
-
During high-pressure calibration, confirm that the adapter’s pressure rating matches the instrument under calibration.
Nexisense supports OEM customization and bulk supply of pressure adapter kits. We can provide personalized combinations based on users’ commonly used specifications or special interface requirements, along with long-term stable supply assurance.
FAQ
Q1. How many pieces does the XY-1 Pressure Gauge Adapter Kit contain? Can it cover most pressure instrument interfaces?
It contains a total of 38 adapter pieces, covering the most commonly used domestic and international thread specifications such as M20, G, NPT, and ZG. It can meet interface conversion needs for more than 95% of pressure gauges and pressure transmitters.
Q2. Does the kit include dedicated adapters for oxygen pressure gauges?
Yes, it includes 1 set of dedicated transition adapters for axial gauges and oxygen pressure gauge verification, which can be safely used for oxygen pressure gauge calibration.
Q3. What is the quantity and type of sealing elements? Do I need to purchase them separately?
It comes with 70 sealing elements of various specifications. In general, there is no need to purchase additional ones, as they can meet long-term usage requirements.
Q4. What is the material of the adapters? Can they be used in high-pressure applications?
They are made of high-quality stainless steel, offering high strength and corrosion resistance. They are suitable for conventional high-pressure calibration applications (specific pressure rating should be determined based on the actual instrument under calibration).
Q5. How to quickly find the corresponding adapter during field calibration?
It is recommended to store adapters classified by specification. All adapters in the kit have clear markings for quick selection.
Q6. Does it support customization of special-specification adapters?
Yes, OEM customization is supported. Adapters can be machined and produced according to special thread or interface requirements provided by users.
Q7. Is it compatible when used with imported pressure calibration equipment?
It is fully compatible and can serve as an interface adapter tool for imported calibration benches, solving interface mismatch issues between domestic and international equipment.
Q8. How to maintain the adapter kit after long-term use?
Clean the adapters promptly after use and keep the threads dry. Regularly check sealing elements for aging and replace them in time. Avoid dropping or bumping to prevent thread damage.
Summary
The Nexisense XY-1 Pressure Gauge Adapter Kit (38-Piece Set) provides an efficient and convenient interface conversion solution for pressure instrument calibration work with its comprehensive specifications, high-quality stainless steel material, and complete sealing accessories. Its one-stop design can significantly improve the work efficiency of metering verification and field calibration. It is a practical tool for metering laboratories, instrument manufacturing enterprises, and engineering maintenance teams.
If your laboratory or project requires a multi-specification pressure adapter conversion tool, please feel free to contact the Nexisense technical support team. We will provide professional selection advice, customized combination solutions, and stable bulk supply services based on your commonly used instrument types, calibration equipment interfaces, and bulk requirements, helping to make your calibration work more efficient.
