Pressure Transmitter Selection Guide: Comprehensive Analysis from Basic Parameters to Error Prevention

2026-01-25

Pressure Transmitter Selection Guide: A Comprehensive Analysis from Basic Parameters to Error Prevention

In the field of industrial automation and process control, pressure transmitters are indispensable instrumentation devices. They convert on-site pressure signals into standard electrical signals, enabling remote monitoring and data transmission. As the professional technical team at Nexisense, we often encounter customers who feel confused when selecting pressure transmitters: What parameters need to be provided? How can common problems be avoided? Based on practical experience, this article starts from key selection points and systematically explores pressure transmitter selection strategies, potential sources of measurement error and optimization methods, and compares pressure transmitters with traditional pressure gauges. Through this content, we aim to provide practical guidance for your equipment selection, ensuring more efficient and reliable system operation.

pressure transmitter selection.png

Basic Principles and Application Scenarios of Pressure Transmitters

A pressure transmitter is essentially a sensor that converts physical pressure into an electrical signal. It is widely used in industries such as petrochemical, pharmaceutical, and water treatment. Its working principle involves a sensing element (such as diffused silicon or ceramic sensors) that detects medium pressure, which is then amplified and converted by circuitry into standard signals such as 4–20 mA or 0–10 V. These signals are transmitted to PLCs, DCS systems, or display instruments for real-time monitoring.

In practical applications, pressure transmitters can measure absolute pressure, gauge pressure, or differential pressure, and adapt to various complex environments. For example, in high-pressure pipeline systems, they ensure timely response of safety valves; in wastewater treatment plants, they help optimize pump station operation. Nexisense pressure transmitter series products are designed with full consideration of industrial field diversity, ensuring stable performance in high-temperature and highly corrosive environments.

Seven Key Parameters for Pressure Transmitter Selection

Proper selection is the key to ensuring optimal performance of pressure transmitters. Below are the seven core parameters summarized by our team to help you systematically define your requirements.

Selection of Wetted Materials

First, evaluate the corrosiveness of the measured medium. Standard pressure transmitters typically use 316L stainless steel for wetted parts, which offers excellent resistance to acids and alkalis and is suitable for most non-corrosive media such as water, air, or oils. If the medium contains chloride ions or strong acids (such as hydrochloric acid), it is recommended to upgrade to Hastelloy C-276 or tantalum materials to extend service life. Nexisense provides customized material options to ensure compatibility and avoid premature failure due to material mismatch.

Determination of Accuracy Class

Accuracy directly affects measurement reliability. Different national standards define accuracy slightly differently. In China and the United States, accuracy is usually based on the 10%–90% of full scale where linearity is optimal, and can reach 0.5% FS (full scale). European standards include edge ranges with poorer linearity, resulting in more conservative accuracy markings, such as 1%. For precision control applications, such as pharmaceutical dosing systems, choosing high-accuracy models of 0.1% or 0.2% is critical. In actual selection, balance budget and application needs to avoid unnecessary cost increases from excessive accuracy requirements.

Reasonable Setting of Measurement Range

The measurement range should cover 1.5–2 times the actual operating pressure to provide a safety margin. For example, for a system operating at 70 bar, a 100 bar range is recommended. This prevents overload damage to the sensor while ensuring optimal linearity within approximately 70% of the range. A range that is too small increases the risk of overpressure failure, while an overly large range sacrifices resolution. Nexisense products support wide turndown ratios for flexible on-site adjustment.

pressure transmitter selection.png

Matching of Output Signals

The output signal must be compatible with the control system. Common types include 4–20 mA (two-wire, strong anti-interference, suitable for long-distance transmission) and 0–10 V (three-wire, easy voltage acquisition). In industrial environments with high electromagnetic noise, 4–20 mA signals are preferred due to their superior resistance to interference. Other options such as HART protocol or RS485 Modbus enable intelligent diagnostics and remote configuration, improving system integration.

Consideration of Medium Temperature

The standard medium temperature range for pressure transmitters is -30°C to +85°C. If this range is exceeded, such as in steam measurement, a siphon or heat sink can be used to cool the medium. High-temperature environments (e.g., refineries) require high-temperature-resistant products. Nexisense high-temperature series can withstand up to 150°C, using ceramic isolation diaphragms to protect electronic components.

Medium Characteristics and Installation Method

Medium characteristics determine whether special structures are required. For easily crystallizing or viscous media such as asphalt or slurry, flush diaphragm or chemical seal designs are recommended to prevent blockage of pressure ports. Installation methods include threaded, flanged, or clamp connections to ensure reliable sealing. Additionally, consider cable outlet direction (rear or side) and protection rating (such as IP67 dustproof and waterproof), especially for outdoor or humid environments.

Other Auxiliary Parameters

Finally, confirm the supply voltage (typically 24 VDC) and process connection interfaces (such as G1/4 or NPT1/2). For special applications like hazardous areas, explosion-proof models (Ex ia IIC T6) are required, along with evaluation of electromagnetic compatibility (EMC). Though these details may seem minor, they significantly impact overall system performance.

By confirming the above parameters, you can create a complete selection specification sheet to ensure perfect compatibility between the device and the application.

pressure transmitter selection.png

Common Error Causes and Mitigation Methods in Pressure Transmitter Operation

Even with correct selection, errors may still occur during operation. Understanding these causes helps optimize installation and maintenance.

Analysis of Potential Error Sources

  • Leakage: Loose impulse line fittings leading to pressure signal attenuation.

  • Wear: Especially when cleaning agents are used, medium erosion can damage sensor surfaces.

  • Heterogeneous substances in pipelines: Gas in liquid lines or liquid in gas lines causing head errors.

  • Temperature differences: Unequal temperatures in impulse lines causing density differences and affecting static pressure calculations.

These issues are particularly prominent in differential pressure measurements, such as flow metering applications.

Practical Strategies to Reduce Errors

  • Shorten impulse line length to reduce friction and leakage risks.

  • For liquid or steam measurement, slope impulse lines upward (slope ≥ 1/12) to prevent gas accumulation.

  • For gas measurement, slope impulse lines downward (slope ≥ 1/12) to prevent liquid retention.

  • Avoid high points (for liquids) or low points (for gases) in impulse lines to maintain uniform flow.

  • Ensure equal temperature on both impulse lines using insulation materials.

  • Use larger diameter impulse lines to reduce friction loss.

  • Remove gas from liquid-filled impulse lines via vent valves and conduct regular checks.

  • Ensure identical fill fluids on both sides when using isolation liquids.

  • Connect cleaning agents near the pressure tap, avoiding flow through the transmitter body.

  • Enhance sealing using O-rings or sealing tape to eliminate leaks.

Nexisense transmitters feature built-in self-diagnostic functions that monitor these conditions in real time and provide early warnings.

Analysis of Differences Between Pressure Transmitters and Pressure Gauges

In field measurements, pressure transmitters and pressure gauges are often confused, but they differ significantly in function and applicability.

Comparison of Output Signals and Functions

Pressure transmitters output standard electrical signals (such as 4–20 mA), enabling integration into automation systems for remote display, alarms, and control. Pressure gauges only provide local mechanical pointer readings without electrical output, suitable for simple on-site observation.

Accuracy and Reliability Differences

Transmitters offer higher accuracy (0.1%–0.5%) with digital compensation, making them suitable for precision control. Pressure gauges have lower accuracy (1.6%–2.5%), are susceptible to vibration, and have poorer long-term stability.

Power Supply and Installation

Transmitters require external power supply (24 VDC) and are available in various forms, including intelligent and dial-integrated types. Pressure gauges require no power supply and have a fixed dial form, offering simple installation but limited functionality.

Application Scenario Selection

For complex systems requiring data logging, transmitters are preferred; for simple monitoring, pressure gauges suffice. Nexisense pressure transmitters surpass traditional gauges in accuracy and durability, providing more comprehensive solutions.

FAQ: Frequently Asked Questions About Pressure Transmitters

  1. How should the range of a pressure transmitter be selected? It is recommended to choose 1.5 times the actual pressure to ensure margin and avoid overload.

  2. What are the advantages of a 4–20 mA output signal? Strong anti-interference, 4 mA zero for line-break detection, suitable for long-distance transmission.

  3. What if the medium temperature is too high? Use siphons or high-temperature transmitters; Nexisense supports customization.

  4. What does FS mean in accuracy class? Full Scale, indicating error relative to the entire range.

  5. What is the difference between a transmitter and a sensor? A sensor only senses pressure; a transmitter includes amplification and output circuits.

  6. How to measure viscous media? Use flush diaphragm designs to prevent blockage.

  7. Where are explosion-proof transmitters used? In flammable and explosive environments such as petrochemical areas.

  8. How often should calibration be performed? Typically once a year, depending on the environment, using standard pressure sources.

  9. What is the role of HART protocol? Enables remote configuration and diagnostics, improving maintenance efficiency.

  10. What is the warranty period for Nexisense transmitters? Standard 2-year warranty with lifetime technical support.

Conclusion

Pressure transmitter selection involves multidimensional considerations, from materials to output signals, each step affecting final performance. With the guidance provided in this article, you can better avoid errors and enhance system stability. Compared with pressure gauges, transmitters demonstrate clear advantages in the era of automation. Nexisense is committed to providing reliable measurement solutions. If you have specific requirements, feel free to consult our technical team to optimize your industrial applications. Choosing the right equipment is not just an investment, but a wise decision to safeguard production safety.