Blog

Industry news

Pressure Transmitter Flange Installation Guide: Ensuring Safe and Efficient Industrial Applications

2026-01-07

Pressure Transmitter Flange Installation Guide: Ensuring Safe and Efficient Industrial Applications

In the field of industrial automation, the correct flange installation of pressure transmitters directly affects equipment stability and safety. Nexisense, a professional sensor brand, is known for its durable and precise flange-mounted pressure transmitters. This article provides a comprehensive analysis of key flange installation considerations, including definitions, principles, structure, advantages, application scenarios, maintenance methods, and technical parameters, helping engineers and operators optimize the installation process and avoid common faults.

Definition of Pressure Transmitter Flange

A pressure transmitter converts physical pressure signals into standard electrical signals and is commonly used to monitor pressure changes in gases, liquids, or steam. A flange-mounted pressure transmitter refers to a device with a flange interface, allowing direct mounting onto pipelines or vessels to achieve a sealed and reliable pressure transfer.

Unlike threaded or clamp connections, flange connections use flat mating surfaces, typically consisting of a flange plate, sealing gasket, and bolt assembly. This design is ideal for large-diameter pipelines or applications requiring frequent disassembly, capable of withstanding higher pressures and temperatures. Nexisense flange transmitters, such as the PT124B-281 model, integrate explosion-proof and corrosion-resistant features suitable for flammable and explosive environments, ensuring safe measurement.

Flange transmitters emphasize modular design for easy integration with existing industrial systems. Standard flange specifications, such as ANSI or DIN, allow seamless matching to various pipeline systems.

8.png

Working Principle of Flange Pressure Transmitters

Flange-mounted pressure transmitters operate based on piezoresistive or capacitive effects. When medium pressure acts on the sensing diaphragm, it produces a small deformation, which is converted to an electrical signal by internal circuitry, usually outputting 4–20 mA or HART signals.

Through the flange connection, pressure is transmitted via an isolation diaphragm to the sensor core, preventing direct contact between the medium and internal components. This is especially important for corrosive or high-temperature media. For example, in a double-flange differential pressure transmitter, high and low-pressure chambers are connected via capillary tubing and filling fluid; the differential pressure drives diaphragm displacement to measure level or flow.

The flange ensures seal integrity and prevents leaks. Nexisense products use silicone oil-filled isolation systems to compensate for temperature-induced errors, ensuring stable output signals. The design leverages Pascal’s law to distribute pressure evenly across the flange surface for accurate transmission.

Flange Structure of Pressure Transmitters

The structure of a flange-mounted pressure transmitter includes the sensor body, flange interface, isolation diaphragm, and electronic module. The sensor body is typically housed in stainless steel, integrating piezoresistive or capacitive sensing elements. The flange interface consists of a flange plate, bolt holes, and seal grooves, supporting flat or insert-type flanges.

The isolation diaphragm, usually made of Hastelloy or tantalum and 0.05–0.1 mm thick, withstands high pressure without deformation. Capillary tubes, up to several meters long, with silicone or fluorinated oil, are used for remote transmitters. The electronic module includes amplification circuits, temperature compensation, and output interfaces, supporting LCD display and remote communication.

Nexisense designs, such as the PT series, feature compact flanges 50–150 mm in diameter and weights of 1–2 kg for easy field installation. The design is seamless with IP65 protection for dust and water resistance. Flange surfaces have O-ring grooves and rubber or PTFE gaskets for zero leakage.

9.png

Advantages of Flange Pressure Transmitters

Flange connections offer superior sealing, with multiple bolts holding pressures up to 1000 bar, far exceeding threaded connections. They allow flexible horizontal or vertical installation with rotational adjustment without affecting zero.

Corrosion resistance and high-temperature adaptability are notable. Nexisense transmitters use special alloy diaphragms for strong acids and alkalis, with a working range of -40°C to 125°C. Maintenance is convenient, as flanges allow quick component replacement, reducing downtime.

Compared to other connection types, flange transmitters perform better under vibration and effectively absorb shocks. Measurement accuracy is high, with total error as low as 0.25% FS, making them suitable for precision control systems. These advantages make flange transmitters a reliable choice in complex conditions, enhancing operational efficiency.

Application Scenarios

Flange pressure transmitters are widely used in petrochemical, power boiler, and pharmaceutical industries. In petrochemicals, they monitor pipeline and reactor pressures to ensure safe transport. In coal mine hydraulic systems, flange connections withstand damp and dusty environments, providing real-time feedback.

In power plants, flange transmitters control boiler steam pressure and handle high-temperature steam while avoiding condensation issues. In pharmaceutical production, they measure liquid levels in sterile vessels, and the flange prevents contamination. They are also used in ship power systems and building HVAC water loops.

For instance, a chemical company using Nexisense flange transmitters reduced pipeline leaks by 30% and significantly improved system stability. These scenarios highlight the adaptability of flange transmitters to high-temperature, high-pressure, and corrosive media, advancing industrial automation.

11.png

Maintenance Methods

Regular maintenance extends transmitter life. Clean flange surfaces and diaphragms with a soft cloth and neutral solvent, avoiding scratches. Inspect gaskets quarterly and replace to prevent aging.

Winter anti-freeze measures are essential, such as using antifreeze or insulation. Install impulse lines in temperature-stable areas and protect from direct sunlight. Check electrical connections and tighten waterproof fittings to prevent water ingress. Do not disassemble during abnormal operation; consult professionals. Nexisense recommends annual calibration to ensure accuracy. Maintenance also prevents blockages, such as flushing impulse ports when measuring crystallizing media.

Technical Parameters

Nexisense flange transmitters cover ranges from 0–1 bar to 0–1000 bar, with accuracy 0.25–0.5% FS and repeatability ≤0.1% FS. Output is 4–20 mA, supply voltage DC 10–30V. Process connections include G1/4 or M20x1.5 threads; flange standards ANSI 150#–600#. Medium temperature -10°C to 70°C, ambient -40°C to 125°C. Overload capacity 150% FS, response time<1 ms. Explosion-proof rating Exia II CT4, protection IP65. Capillary lengths 1–10 m are customizable.

Installation Considerations

Key considerations include maintaining proper flange distance from structures or supports to reduce vibration interference, checking flanges and gaskets for defects, and ensuring waterproof cable connections. When measuring gas, place pressure ports at the top of pipelines to allow liquid drainage.

For outdoor winter installations, protect against freezing to prevent liquid expansion damage. Install impulse lines in temperature-stable zones; for high-temperature media, connect a condenser to control transmitter temperature. Tighten bolts gradually, ensuring even sealing. The transmitter body can rotate within the flange, but mating surfaces should remain vertical. Horizontal installations require zeroing to eliminate hydrostatic head effects. Following these practices reduces fault risk.

FAQ

Which media are flange transmitters suitable for?
Gases, liquids, and steam, especially corrosive or high-temperature media such as chemical reagents and steam.

How to manage temperature effects during installation?
Use condensers or buffer tubing to keep transmitter temperature within limits.

Maintenance frequency?
Clean monthly, check seals quarterly, and calibrate annually.

Difference from threaded connections?
Flanges provide better sealing, are suitable for high-pressure large-diameter applications, and offer flexible installation.

Supported protocols?
Standard 4–20 mA, optional HART for system integration.

Conclusion

Pressure transmitter flange installation impacts industrial safety and efficiency. Understanding definitions, principles, structure, advantages, applications, maintenance, and technical parameters helps users apply Nexisense products effectively. Proper installation and maintenance prevent hazards and optimize performance. Choosing reliable flange transmitters ensures stable production, and Nexisense series products are well-suited for specific operational requirements.

Send Inquiry(Tell us your requirements,Let's discuss more about your project,we can do more.)