Application of Computer Room Temperature and Humidity Transmitters in Environment Monitoring

2025-12-27

Application of Computer Room Temperature and Humidity Transmitters in Computer Room Environment Monitoring

With the rapid development of information technology, cloud computing, and digital business, computer rooms have become critical infrastructure for enterprise and institutional operations. A large number of high-value and high-density electronic devices such as servers, switches, routers, and storage arrays operate continuously for long periods, placing higher demands on the stability of the computer room environment. Among these factors, temperature and humidity are the most easily overlooked yet potentially destructive environmental parameters.

Once temperature and humidity in a computer room become uncontrolled, minor issues may include degraded equipment performance and increased failure rates, while severe cases may lead to system downtime, data loss, or even hardware damage. Therefore, establishing a scientific, reliable, and sustainable computer room temperature and humidity monitoring system has become a fundamental component of computer room construction and operation.

Temperature and Humidity Sensor33.png


What Is a Computer Room Temperature and Humidity Transmitter

A computer room temperature and humidity transmitter is an industrial-grade monitoring device used to measure and output real-time ambient temperature and relative humidity data in computer rooms. It typically uses high-precision temperature and humidity sensors and transmits collected data stably to upper-level systems, dynamic environment monitoring systems, or cloud platforms through standard communication protocols such as RS485 / Modbus RTU, enabling centralized monitoring, data analysis, and alarm linkage.

Compared with ordinary temperature and humidity sensors, dedicated computer room temperature and humidity transmitters better meet the requirements of data centers and communication rooms in terms of accuracy, stability, anti-interference capability, and long-term operational reliability.


The Necessity of Computer Room Temperature and Humidity Monitoring

Electronic Devices Are Highly Sensitive to the Environment

Modern computer rooms contain dense electronic components. Heat conduction, convection, and radiation occur between devices, and changes in temperature and humidity directly affect the aging speed and reliability of electronic components.

Risks of Temperature Loss of Control

Research and practice show that when the ambient temperature increases by 10°C, the service life of many electronic components decreases significantly, and the lifespan of some sensitive components may be reduced by more than 50%. Conversely, when the computer room temperature drops below 5°C, some equipment may fail to start properly. Under extreme low-temperature conditions (such as −40°C), lead-acid batteries will be unable to provide effective energy.

Hidden Dangers of Abnormal Humidity

Computer rooms are generally recommended to maintain relative humidity between 40% and 50%.

  • When humidity exceeds 65%, water films may form on equipment surfaces, creating “conductive paths” that seriously threaten circuit reliability.

  • When humidity falls below 40%, personnel movement can easily generate electrostatic discharge. Static electricity is known as the “invisible killer” in the electronics industry and may cause irreversible damage in an instant.

    Temperature and Humidity Sensor34.png


Working Principle of Nexisense Computer Room Temperature and Humidity Transmitters

Nexisense computer room temperature and humidity transmitters use high-precision digital temperature and humidity sensors to sense ambient air temperature and moisture content in real time. After converting analog signals into digital signals, the data undergo internal calibration, compensation, and stabilization processing, and are then output as standard data via the RS485 interface using the Modbus RTU protocol.

These data can be read in real time by dynamic environment monitoring systems, building automation systems, or cloud platforms for display, storage, analysis, and linkage control.


Structural Composition and Design Features

Core Sensing Unit

High-precision integrated temperature and humidity sensors are adopted, featuring fast response, wide measurement range, and minimal long-term drift, making them suitable for 24/7 continuous operation.

Communication and Power Supply Structure

The device integrates an RS485 communication interface and adopts an RJ45 design, combining communication and power supply into one interface. It supports multi-device cascading and reduces wiring complexity.

Control and Configuration Unit

Built-in DIP switches enable rapid configuration of device addresses and communication baud rates, facilitating on-site deployment and maintenance.

Display and Interaction

Some models support OLED or LCD displays, allowing on-site viewing of temperature, humidity, address, and communication status, with clear visibility even at night.


Advantages of Nexisense Computer Room Temperature and Humidity Transmitters

  • High measurement accuracy and stable data, meeting long-term monitoring requirements of data centers

  • Standard RS485 communication, compatible with mainstream dynamic environment and building management systems

  • Support for cascading and centralized power supply, simplifying engineering wiring

  • Multiple installation methods, suitable for cabinets, walls, and other scenarios

  • Easy deployment and maintenance, reducing operation and maintenance costs

In practical applications, these designs not only improve system reliability but also reserve space for future expansion and upgrades.

Temperature and Humidity Sensor35.png


Typical Application Scenarios

Data Centers and Server Rooms

Used to monitor temperature and humidity distribution in hot and cold aisles, cabinet fronts and backs, and air-conditioning supply and return air areas, supporting refined cooling management.

Communication Rooms and Base Stations

Ensure that communication equipment operates stably within the environmental ranges specified by national standards, reducing failure rates.

Financial, Government, and Enterprise Information Centers

Meet high-grade computer room requirements for environmental traceability, auditability, and remote operation and maintenance.

Edge Computing and Unattended Computer Rooms

Combined with cloud platforms and alarm systems to achieve environmental safety monitoring under unattended conditions.


Measurement Methods and System Integration

Nexisense computer room temperature and humidity transmitters are typically connected to dynamic environment monitoring hosts or gateways via RS485 buses and then uploaded uniformly to local monitoring platforms or cloud systems.

The system can achieve:

  • Real-time data acquisition and curve display

  • Historical data storage and report export

  • Over-limit alarms (SMS, platform, sound and light, etc.)

  • Linkage control with air conditioners, dehumidifiers, and other equipment


Installation, Maintenance, and Daily Care

Installation Recommendations

  • Avoid direct airflow from air conditioner outlets and heat sources

  • Deploy monitoring points covering cabinet fronts and backs or critical areas

  • Ensure standardized communication bus wiring and avoid strong electrical interference

Maintenance Key Points

  • Regularly check communication status and data stability

  • Perform periodic calibration in long-term operation environments

  • Keep device surfaces and ventilation openings clean to avoid dust affecting response


Reference Technical Parameters (Illustrative)

  • Temperature measurement range: −20°C to +60°C

  • Humidity measurement range: 0 to 100% RH

  • Communication method: RS485

  • Communication protocol: Modbus RTU

  • Power supply method: Centralized power supply / bus power supply

  • Installation methods: Cabinet mounting, magnetic attachment, wall mounting

(Specific parameters are subject to actual Nexisense model specifications.)


Frequently Asked Questions (FAQ)

How often should temperature and humidity be collected in a computer room?
It is generally recommended to collect data every 1 to 5 minutes to ensure real-time performance while facilitating data analysis.

Is it necessary to connect to a cloud platform?
It is not mandatory, but cloud platforms enable remote viewing, data analysis, and alarm notifications, making them more suitable for multi-site or unattended scenarios.

How many transmitters are needed for one computer room?
This depends on the room area, number of cabinets, and hot/cold aisle layout. It is generally recommended to deploy devices by zones and key monitoring points.


Conclusion

Computer room temperature and humidity transmitters are fundamental devices for ensuring the safe and stable operation of data centers and communication rooms. By deploying Nexisense computer room temperature and humidity transmitters, continuous and precise monitoring of environmental parameters can be achieved, deeply integrating with dynamic environment systems and cloud platforms to build a visualized, alarm-enabled, and linkage-capable intelligent computer room environment management system.

In the context of accelerating digitalization and intelligent operation and maintenance, scientific temperature and humidity monitoring is no longer optional but a critical safeguard for the long-term stable operation of computer rooms.