Ventilation Duct Temperature and Humidity Monitoring: Comprehensive Analysis of Nexisense Duct Sensors
In modern buildings, ventilation ducts are a critical component of air conditioning systems, ensuring air circulation and occupant comfort. However, the hidden risks inside ducts are often overlooked. Suitable temperature and humidity conditions can become breeding grounds for bacteria and fungi, which are then carried indoors by airflow and pose health threats. Nexisense duct temperature and humidity sensors are specifically designed for this scenario, providing precise monitoring solutions. This article explores the necessity of monitoring and analyzes system details to help build a safer air environment.
Analysis of Monitoring Necessity
Pollutants inside ventilation ducts are not limited to dust but also include microorganisms such as bacteria and fungi. The temperature and humidity conditions inside supply air ducts are particularly favorable for their survival and reproduction. When air conditioning systems start or ducts vibrate, dust carrying pathogens can easily be resuspended and spread indoors. This directly increases the risk of respiratory diseases among occupants and may even trigger sick building syndrome, a collection of symptoms such as headaches and fatigue caused by indoor environmental factors.
Unmonitored ducts act as invisible threats where pollutants accumulate silently. Real-time temperature and humidity data can reveal anomalies early, enabling system adjustments to inhibit microbial growth and ensure clean air. This is not only a health requirement but also a key aspect of modern building management.
System Definition and Working Principle
Nexisense duct temperature and humidity sensors are designed specifically for monitoring inside air ducts. They use imported high-precision measurement units, typically based on capacitive humidity sensing and thermistor temperature detection. The humidity element captures moisture through changes in dielectric capacitance, while the temperature element senses heat conduction, resulting in low drift and fast response.
The system supports the standard Modbus-RTU protocol, ensuring stable and reliable data transmission. This principle enables accurate capture of environmental changes in dynamic airflow while avoiding external interference and providing reliable baseline data.
Structural Analysis
The sensor structure emphasizes practicality and durability. The core probe is made of stainless steel and equipped with a 25 μm high-density filter, which filters dust particles while maintaining adequate airflow. Installation uses a flange-mount design with a high-quality silicone sealing ring to prevent air leakage.
The housing features a waterproof design and includes a high-brightness color LED display that cyclically shows real-time values for easy viewing in low-light environments. Anti-interference circuitry resists electromagnetic disturbances from inverters and similar equipment. The overall design is compact and well suited for duct integration.

Key Advantages
Why choose a dedicated duct sensor instead of a general-purpose sensor? Conventional sensors often require separate drilling, and mismatched probes and cables can easily cause air leakage, affecting measurement accuracy. While adhesive mounting is possible, it complicates maintenance and relocation.
Nexisense uses a flange-mounted sealed installation that requires only a single opening, ensuring airtightness while allowing easy adjustment. The filter is resistant to high dust and humidity levels and offers long service life. The temperature range is flexible, with a default of −40 to 80 ℃ and optional adjustment to ranges such as 0 to 50 ℃ to suit different applications.
The system offers strong expandability: communication cable length up to 2000 meters, support for networking up to 254 devices, and secondary development capabilities. The LED display and waterproof housing enhance on-site usability. These design choices reduce installation challenges and improve long-term reliability.
Application Scenarios
The sensor is widely used in HVAC systems for commercial buildings, hospitals, office buildings, and factories. In high-requirement environments such as hospitals, monitoring helps prevent microbial spread and protect vulnerable populations. In office environments, it improves comfort and reduces the incidence of sick building syndrome.
In industrial plants with high dust levels, the advantages of the stainless steel filter are particularly evident. Large building complexes can implement centralized monitoring through networking, making the solution suitable for schools, shopping malls, and other densely populated areas. Combined with cloud platforms, it also supports remote management and improves overall air quality control.

Detailed Measurement Method
The measurement process is continuous and automated. The probe is placed directly in the airflow to sense temperature and humidity changes in real time. Data is transmitted via the Modbus protocol, supporting local data acquisition or upload to environmental management software.
Users can customize measurement ranges and alarm thresholds. Installation ensures the probe is positioned perpendicular to airflow to avoid turbulence interference. The sealed design prevents air leakage, ensuring measurements are not affected by duct pressure and accurately reflect internal environmental conditions.
Installation Guide
Installation is simple and efficient. Drill a suitable opening in the duct, secure the flange, insert the probe, and adjust the insertion depth. The silicone sealing ring ensures airtightness, and the communication cable is connected with address configuration.
After powering on, the LED display is used to verify readings. Compared to standard sensors, no additional sealing is required, and maintenance removal is straightforward. Technicians can complete installation by following the manual, significantly reducing construction time.

Maintenance and Care Guide
Ease of maintenance is a key feature of the system. Quarterly cleaning of the filter is recommended, using a soft cloth to wipe the probe and avoid scratches. Inspect the sealing ring for aging and replace it if necessary.
The waterproof housing minimizes the impact of humidity, and the anti-interference circuitry ensures stable operation. Regular calibration can be performed via software, and the cloud platform monitors device status and issues alerts for anomalies. These steps require minimal intervention and extend equipment lifespan.
Technical Parameter Overview
Temperature range −40 to 80 ℃ (adjustable to multiple ranges), humidity range 0–100% RH, high accuracy with low drift. Communication via Modbus-RTU, cable length up to 2000 meters, networking up to 254 devices.
High protection rating, LED color display, and 25 μm stainless steel filter. These parameters meet industrial and building application requirements, ensuring long-term measurement accuracy.

Frequently Asked Questions (FAQ)
Can ordinary sensors replace duct-specific sensors?
Not recommended, as they can cause air leakage, affect accuracy, and are inconvenient to maintain.
How is high-dust environments handled?
The stainless steel filter effectively filters dust while maintaining airflow.
Does the system support remote viewing?
Yes, data can be uploaded to cloud software for multi-terminal access.
How is the measurement range adjusted?
Ranges can be customized according to application needs.
Will installation affect duct airflow?
The sealed design minimizes interference and ensures accurate measurement.
Conclusion
Ventilation duct temperature and humidity monitoring is not only a technical requirement but a core component of health protection. Nexisense duct sensors, with their precise and reliable design, help users prevent microbial risks and improve air quality. From daily office environments to critical medical settings, they provide strong support. Investing in intelligent monitoring delivers long-term comfort and safety, allowing buildings to breathe cleaner air.