An IP rating is a useful procurement reference, but it does not describe every environmental condition of an installed pressure measurement system. The connector, cable entry, enclosure and service practices can all affect the assembly. Selecting a sensor by the largest protection code alone is not a complete installation review.
This guide is intended for engineering companies and OEMs comparing published Nexisense pressure sensor references. It does not reproduce a protection standard or assign an unverified immersion depth, duration, cleaning resistance or certification to a product. Obtain the applicable conditions for the exact supplied assembly.

Application Requirements for System Integrators
Describe the exposure at the actual location: weather, condensation, splash, planned immersion, cleaning, cable movement and maintenance access. A cabinet-mounted sensor and a submerged level probe present different requirements. State those conditions in the enquiry rather than asking only for a particular code.
Review the complete path from the sensor to the receiving panel. An exposed cable termination or an incorrectly assembled connector can become the weak point even when the sensing body has an appropriate published rating. Include spare-part and reconnection practices in the project review.
Nexisense Product Reference
The Nexisense FST100-1002 parameter table lists IP65 for the sensor and separately mentions an IP67 connector option. YF-P200 lists IP68 for the level transmitter. These references do not establish that a connector option changes the rating of the entire sensor or that a protection code alone specifies unlimited immersion conditions.
Product specification (English): FST100-1002
Product Parameters and Procurement Checks
| Parameter | Published Reference | Engineering Check |
|---|---|---|
| FST100-1002 sensor entry | IP65 | Confirm the supplied configuration and installation conditions. |
| FST100-1002 connector option entry | IP67 | A component entry does not independently define the complete assembly. |
| YF-P200 protection entry | IP68 | Request the specified immersion conditions and cable assembly limits. |
| YF-P200 supply reference | 8-32 V DC | Protection suitability does not replace an electrical supply review. |
| FST100-1002 working temperature | -40 to +85 C | Evaluate environmental temperature separately from ingress protection. |
Selection Guide
Ask which parts and assembly conditions the quoted rating covers, including the mating connector and cable gland. Obtain instructions for connector engagement, sealing components and any required maintenance. Do not assume that an unplugged connector provides the same protection as a correctly completed assembly.
For immersion or aggressive cleaning, request explicit written conditions for depth, duration, medium, temperature and cable termination. A generic protection entry should not be converted into an application-specific guarantee. Review material compatibility and corrosion separately from ingress protection.

Integration, Installation and Commissioning
Locate cable joints and terminations according to the approved design and the supplied instructions. Provide strain relief and routing that avoid repeated mechanical loads on the seal. Protect any required reference vent without blocking its function; a vented level cable needs an installation-specific termination arrangement.
During commissioning, inspect the delivered seals, mating connector and enclosure entries against the approved bill of materials. Record the completed assembly condition. Use only the agreed environmental or mechanical acceptance procedure; an informal water exposure test is not a substitute for applicable manufacturer evidence.
After maintenance, verify that the correct seals and connector parts have been restored. Investigate moisture-related symptoms before adjusting calibration. A cable or enclosure issue can affect data quality without indicating a pressure sensing element problem.
Illustrative Project Application
Illustrative engineering example: a contractor specifies a level transmitter for a wet installation and places the cable junction according to the supplier termination instructions. The review checks the probe, cable and junction as an assembly rather than treating the IP68 entry as a complete site specification. No immersion depth or customer outcome is asserted.

Why Consider Nexisense
Nexisense publishes protection references across low-power pressure and level measurement families. Send the actual exposure and cable termination requirements with the enquiry. Configuration-specific documentation allows the supplier rating to be evaluated against the intended installation rather than used as a standalone buying shortcut.
Frequently Asked Questions
Q1. Does an IP rating cover every environmental hazard?
No. Temperature, corrosion, chemical exposure, vibration and other conditions require separate review for the actual installation.
Q2. Does an IP67 connector make an IP65 sensor assembly IP67?
Do not infer a complete-assembly rating from one component entry. Ask which configuration and assembly conditions the manufacturer rating covers.
Q3. Does IP68 mean unlimited immersion?
No unlimited depth or duration should be inferred. Obtain the conditions specified for the supplied probe and cable assembly.
Q4. Can a connector be left unplugged in a wet location?
Use the supplied protection and assembly instructions. Do not assume an unassembled connection retains the completed assembly rating.
Q5. Is corrosion resistance the same as ingress protection?
No. Evaluate the process medium and external exposure against the actual materials and seals separately.
Q6. Should a vented cable be sealed completely?
Do not block a required pressure reference path. Follow the manufacturer termination instructions while addressing moisture protection.
Q7. Can moisture-related faults always be corrected by recalibration?
No. First inspect the cable, connector and enclosure arrangement. Calibration changes cannot repair an unsuitable environmental installation.
Q8. What should be recorded at handover?
Record the supplied protection configuration, connector and seals, cable termination, exposure assumptions and applicable installation instructions.
Summary
Use a protection code as one input to a complete installation specification. Connector assembly, cable termination, exposure conditions and maintenance controls need to support the same environmental requirement as the pressure sensor body.
Further reading: Related Nexisense product specification (English); Existing pressure transmitter engineering guide (English)