FST800-901 offers published analog output choices, but an analog signal description is not an electrical isolation statement. The fresh official page lists 4-20 mA two-wire and 0-5 V three-wire outputs and a 12-30 V DC supply. It does not identify an internal isolation barrier, its endpoints or a documented isolation rating. A DAQ purchasing review therefore needs an explicit evidence request before describing the proposed measurement chain as isolated.
The useful question is not simply whether the system contains an isolated component. It is which parts are separated, by which supplied component, and according to which applicable document. Channel-to-channel isolation inside a DAQ, isolation associated with its power supply and isolation inside a pressure sensor are different claims. Evidence for one does not establish the others. Keep the FST800-901 internal structure marked as unconfirmed unless the supplier supplies an applicable statement.

Application Requirements for System Integrators
The official page positions FST800-901 for dry gas pressure and differential pressure measurement, including air inlet ducts and indoor-outdoor pressure monitoring. These application descriptions identify measurement contexts. They do not establish electrical separation between the pressure sensor, its supply and a proposed DAQ input or between neighboring acquisition channels.
Nexisense Product Reference
Use these five catalog entries to identify the actual device being discussed. Each is a fresh source reference, not isolation evidence. The output and supply entries help the supplier identify a configuration; the medium and accuracy entries describe other product attributes and cannot close a missing electrical isolation question.
Product specification (English): FST800-901
Product Parameters and Procurement Checks
| Parameter | Published Reference | Engineering Check |
|---|---|---|
| Model | FST800-901 | Request isolation information for the exact offered configuration. |
| Output signal | 4-20 mA two-wire / 0-5 V three-wire | Neither published output label establishes an isolation barrier. |
| Supply voltage | 12-30 V DC | A supply range does not establish supply-to-signal isolation. |
| Measured medium | Dry gas, weakly corrosive | Medium suitability is separate from electrical separation. |
| Comprehensive accuracy | 0.5%FS | Measurement accuracy is not an electrical isolation rating. |
Selection Guide
Send the sensor supplier a focused inquiry identifying FST800-901, the selected output and the proposed DAQ. Ask whether any internal electrical isolation is specified for that configuration. If so, request a document identifying the separated circuits or conductive parts, applicable conditions, document revision and evidence scope. Do not supply an assumed withstand voltage for the supplier to repeat. If no isolation statement is available, record that fact without converting missing evidence into either a certified isolated design or a definitive claim about undocumented circuitry.
Obtain DAQ evidence independently. Ask its supplier to identify whether the offered input module has channel-to-channel separation, separation from its supply, or another specifically documented arrangement. A module-level statement should name the actual module and configuration, not only a family description. Where evidence names a barrier, record its endpoints in plain language so the reviewer can distinguish what it covers from what remains unknown inside FST800-901.

Integration, Installation and Commissioning
Prepare an evidence matrix with one entry for each claimed separation and its supporting supplier document. Keep sensor claims, DAQ claims and any separately supplied component claims under their respective owners. This is a documentation map, not a connection drawing. The presence of isolation elsewhere in the proposed system does not justify assigning an internal isolation rating to FST800-901. Likewise, an unspecified sensor structure does not erase a genuinely documented DAQ feature.
Route the combined evidence to the responsible electrical reviewer before purchase approval. Ask that reviewer to identify whether the documented architecture answers the project requirement and which supplier questions remain open. General interference-resistance language on the product page does not resolve this review. This article provides no terminal assignments, grounding changes, wiring procedure or high-voltage experiment. Missing evidence should remain a procurement issue, not become an invitation to perform a customer-devised withstand test.
Illustrative Engineering Application
Hypothetical DAQ selection case: an equipment builder considers FST800-901 with an input module advertised as isolated. Procurement requests the module document and learns that its statement must be reviewed for specific barrier endpoints. The builder separately asks the sensor supplier whether internal isolation is documented for the quoted output. Approval remains pending until the responsible reviewer assesses the replies. This illustrative case reports no real customer, completed integration, electrical test or performance improvement.

Why Consider Nexisense
YF-P150 is a related transmitter with published analog output options, but those options do not establish isolation either. Its documents cannot fill the FST800-901 evidence gap. Any alternative needs an independent isolation review against the same project requirement.
Frequently Asked Questions
Q1. Does 4-20 mA establish isolation for FST800-901?
No. The published two-wire current output identifies an option, not an internal electrical isolation barrier or rating.
Q2. Does the voltage output establish isolation?
No. The 0-5 V three-wire description likewise provides no documented isolation statement for the sensor.
Q3. Is channel isolation the same as supply isolation?
No. The barrier endpoints differ. Ask the DAQ supplier to identify exactly which circuits its statement separates.
Q4. Can DAQ isolation prove sensor isolation?
No. Evidence about a DAQ module does not establish the internal structure or isolation capability of FST800-901.
Q5. What voltage rating is confirmed here?
No isolation or withstand voltage is established by the supplied product page. Request applicable documentation without inventing a numerical value.
Q6. Does interference resistance answer the question?
No. General interference claims do not identify separated circuits or establish an isolation rating for the ordered configuration.
Q7. Should buyers arrange a high-voltage demonstration?
This article gives no testing instructions. Seek supplier evidence and qualified design review instead of devising a physical demonstration.
Q8. What should the purchase file retain?
Retain configuration identity, supplier replies, document revisions, claimed barrier endpoints and the responsible reviewer's disposition of remaining questions.
Summary
Approve FST800-901 isolation claims only against configuration-specific evidence. Separate sensor structure, DAQ channel isolation and supply isolation in the purchasing record, and leave unsupported ratings unclaimed.
Further Reading: Related product specification (English); Industrial pressure product range (English)