PRODUCTS

Gas Sensors & Detectors

NEXI-MIC-600-S-4-A Online Composite Gas Detector and Alarm (CO
video
product name

NEXI-MIC-600-S-4-A Online Multi-Gas Detection Alarm,Petrochemical/Environmental Engineering/Pharmaceutical Workshop,RS485

Brand: Nexisense

Model: MIC-600-S-4-A

Output: RS485, 4-20mA, 0–5V/1–5V, relay, optional wireless

Power: 24V DC,≥1A

IP Rating: IP66

Range: CO: 0–1000ppm; H₂S: 0–100ppm; O₂: 0–30%Vol; Ex: 0–100%LEL

Description: The Nexisense MIC-600-S-4-A online multi-gas detector and alarm supports the detection of four gases: CO, H₂S, O₂, and Ex. It utilizes advanced electrochemical, catalytic combustion, and infrared technologies, making it suitable for industrial applications in petroleum, chemical, environmental protection, and pharmaceutical industries. Explosion-proof and corrosion-resistant, it features a high-definition color screen display and multiple signal outputs, meeting industrial-grade gas detection and safety alarm requirements.

Products Description
Nexisense MIC-600-S-4-A Online Multi-Gas Detection Alarm

Product Definition: Industrial-Grade Solution forMulti-Gas Monitoring

The NexisenseMIC-600-S-4-A Online Multi-Gas Detection Alarm is a fixed online multi-gas detection system designed for continuous monitoring of hazardous and combustible gases in industrialenvironments. Integrating advanced electrochemical, catalytic combustion, infrared, and PID sensor technologies, it offers real-time monitoring of CO,H₂S, O₂, and Ex gases. Features include local audible-visual alarms, data logging, remote communication, and system integration, makingit ideal for safety control and environmental supervision.

Working Principle: Advanced Sensor Integration for Accurate Readings

The device incorporates a variety of sensor technologies for precise gas detection:

  • Electrochemical Sensors: For CO, H₂S, and O₂ – high sensitivity and strongselectivity through chemical reaction and current output.

  • Catalytic Combustion: For Ex gases– detects heat changes from catalytic oxidation to determine gas concentration.

  • Infrared Sensors (Optional): For CO₂ and hydrocarbons – based on infrared absorption characteristics.

  • PID Photoionization (Optional): Detects VOCs for special industrial requirements.

With multi-stage signalprocessing and temperature compensation algorithms, it ensures stability and avoids drift or false alarms.

Structural Analysis: Durable, Industrial-Grade Build

The Nexisense MIC-600-S-4-A Online Multi-Gas Detection Alarm features a modular design with robust housing:

  • Explosion-Proof Aluminum Alloy Housing: With fluorocarbon coating for corrosion and wear resistance.

  • Industrial TFT Color Screen: 2.5-inch display with Chinese/English interface and graphical menus.

  • Sealed Structure: IP66 protection against dust, water spray, and impact.

  • Multi-signal Output: RS485, 4-20mA, voltage output, relay – easy integration with PLC, DCS systems.

Detection Methods: Flexible Installation Options

Various sampling modes are supported to suit complex environments:

  • Diffusion Type (Standard):Fast response, easy installation.

  • Pipeline Type: For closed systems with flange orthreaded mounting.

  • Pump Suction (Optional): For long-distance or harsh environments, up to 40m range.

  • Flow-Through Sampling: For analytical setups or laboratories.

Application Scenarios: Industry-Wide Gas Safety Monitoring

  • Petrochemical plants – leak detection and process safety

  • Environmental engineering – air and exhaust gas monitoring

  • Pharmaceutical workshops – toxic gas leak alarms

  • Industrial warehouses – oxygen concentration and explosion prevention

  • Laboratories – accurate gas composition analysis

Nexisense MIC-600-S-4-A Online Multi-Gas Detection Alarm Core Specifications

ItemSpecification
ModelNexisense MIC-600-S-4-A
Detected GasesCO, H₂S, O₂, Ex (up to 6 gases optional)
SensingPrinciplesElectrochemical, Catalytic, Infrared, PID, Thermal conductivity
Detection RangesCO: 0–1000ppm; H₂S: 0–100ppm; O₂: 0–30%Vol; Ex: 0–100%LEL
ResolutionCO: 0.1ppm; H₂S: 0.01ppm; O₂: 0.01%Vol; Ex: 0.1%LEL
Accuracy≤±2%F.S
Response Time(T90)≤20 seconds
Output SignalsRS485, 4-20mA, 0–5V/1–5V, relay, optional wireless
AlarmAudible-visual, triple-level relay output
InstallationWall, pipe, flange, or thread mounting
Power Supply24V DC,≥1A
Temperature & Humidity-40°C to +120°C; 0–100%RH (optional)
Explosion ProofExdⅡCT6
Protection LevelIP66 (with optionalrain shield)
Data Storage100,000 logs onboard; SD card supported
Weight & Dimensions1.8kg / 240×180×90mm (lamp height: 230mm)
CertificationsGB15322.1-2003, GB3836.1/2/4-2010, EMC/EMI

Nexisense MIC-600-S-4-A Online Multi-Gas Detection Alarm, Key Features

  • Error-proof calibration and operationlocking

  • Sensor lifetime monitoring and maintenance alerts

  • Remote configuration and infrared control support

  • Adaptable to high humidity/dust/high-temperature environments

  • Capable of linking to fans, solenoid valves, and alarms for active control

Conclusion: A New Benchmark in Industrial Gas Detection

The Nexisense MIC-600-S-4-A Online Multi-Gas Detection Alarm redefines online gas detection by combining precision sensing with smart integration. Offering real-time detection, multi-signal output, and intelligent control, it ensures safe operations in the mostdemanding industrial settings. Widely adopted in petrochemical, pharmaceutical, and environmental sectors, it is the ideal solution for enterprises prioritizing safety, accuracy, and compliance.

For technical manuals, wiring diagrams, or customization consultations, please contact Nexisense technical support.

Send Inquiry(Tell us your requirements,Let's discuss more about your project,we can do more.)