NEXI-GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm,Petroleum/chemical/environmental,RS485

Brand: Nexisense

Model: GTYQ-MIC-600

Output: RS485

Power: 12–30V DC (24V recommended)

IP Rating: IP66

Range: CO: 0–1000 ppm, H2S: 0–100 ppm, O2: 0–30%Vol, Ex: 0–100%LEL

Description: The Nexisense GTYQ-MIC-600 stationary multi-gas detector and alarm provides an advanced multi-gas monitoring solution suitable for various industries such as petroleum, chemical, pharmaceutical, and environmental protection. It can detect hazardous gas concentrations in real time and provide alarm signals. The device features high precision, supports multiple detection principles (electrochemical, infrared, catalytic combustion, etc.), and allows data sharing via wireless transmission and remote monitoring. The product meets the requirements for high explosion-proof, corrosion-resistant, and high-temperature operating environments, making it an indispensable safety tool in hazardous environments.

Products Description
Nexisense GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm

Nexisense GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm Product Definition & ApplicationFields

The Nexisense GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm  is a high-precision, multi-functional gas detectionalarm designed for continuous online monitoring of hazardous gases such as CO, H2S,O2, and combustible gases. It is widely used in petroleum, chemical, power, pharmaceutical, and environmental industries to ensure operational safety.

Capable of detecting upto six gases simultaneously, it features high-resolution sensors, real-time alarms, and multiple communicationprotocols including RS485, 4–20 mA, and wireless transmission.

Typical Applications:

  • Petrochemical plants: Prevent explosionsand poisoning by monitoring gas leaks

  • Pharmaceutical & food industry: Ensure cleanroomstandards

  • Environmental monitoring: Track pollutant emissions

  • Industrial safety: Monitor confinedspaces, storage areas, or hazardous sites

Detection Principles

The Nexisense  GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm supports various sensing technologies depending on the gas type:

  • Electrochemical: Detects gases like CO, H2S, O2 via electrode reactions generating measurable current/voltage.

  • Infrared (NDIR): Uses gas-specific IR absorption to detect gases such as CO2 and hydrocarbons.

  • Catalytic Combustion: Measures heatreleased from gas oxidation on catalysts, ideal for flammable gases.

  • Thermal Conductivity: Measures differences in heat conduction to detect gases like H2 and He.

  • PID (Photoionization): Ionizes VOCs underUV light and measures resulting currents, suitable for benzene, toluene, etc.

Structural Design

The Nexisense GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm features a rugged, explosion-proofenclosure certified to ExdⅡCT6 standards, built from corrosion-resistant materials for harsh environments. The internal architecture includes multiplegas sensors, digital processing circuits, and a high-resolution display for real-time readings.

Nexisense GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm Main Components:

  • Sensor Module: Uses world-classsensors for reliable multi-gas detection

  • Display: 2.5-inch color LCD for gas concentration, temperature, humidity, and alarms

  • ProcessingCircuit: Accurate real-time signal processing

  • Alarm System: Visualand audible alarms with relay output for pre-set thresholds

  • Communication Interface: Supports RS485 (Modbus-RTU),4–20 mA, and wireless options

Measurement Methods

  • Online Continuous Monitoring: Supports diffusion, pipe-type, flow-through, or pump suction sampling

  • Temperature & Humidity Measurement: Integrated Swiss capacitive digital sensor for accurate environmental data

  • Data Storage: 100,000+ data log capacity with real-time, timed, and event-triggered recording. Data exportable via RS485

Nexisense GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm Technical Specifications

ParameterSpecification
Detected GasesCO, H2S, O2, Ex (up to 6 gases)
Detection RangeCO: 0–1000 ppm, H2S: 0–100 ppm, O2: 0–30%Vol, Ex: 0–100%LEL
ResolutionCO: 0.1 ppm, H2S: 0.01 ppm, O2:0.01%Vol, Ex: 0.1%LEL
Sensor TypeElectrochemical,Infrared, Catalytic, Thermal Conductivity, PID
Sensor LifespanEC: 2–3 years, O2:2 years, IR:5–10 years, Catalytic: 3 years
Temperature Range-40℃ to +120℃ (optional)
Humidity Range0–100%RH (optional)
Accuracy≤±2% F.S for gas, ±0.5℃ for temp, ±3%RH for humidity
Response TimeT90 ≤ 20s
Power Supply12–30V DC (24V recommended)
Ingress ProtectionIP66
InstallationWall-mounted or pipe-mounted
Weight1.8 kg

Nexisense GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm Product Summary

The Nexisense GTYQ-MIC-600  fixedmulti-gas detection alarm is a robust and reliable solution for comprehensive gas safety monitoring. Featuring highprecision, versatile detection principles, and flexible communication options, it ensures real-time gas concentration tracking under themost demanding conditions. Whether for industrial manufacturing, environmental regulation, or hazardous material storage, this device is your trusted safetypartner.

Contact our sales team today to explorehow Nexisense GTYQ-MIC-600 Fixed Multi-Gas Detection Alarm can enhance your operational safety and regulatory compliance.

Send Inquiry(Tell us your requirements,Let's discuss more about your project,we can do more.)